Login to myESAIC Membership
Back

About

The ESAIC is dedicated to supporting professionals in anaesthesiology and intensive care by serving as the hub for development and dissemination of valuable educational, scientific, research, and networking resources.


Back

Congresses

The ESAIC hosts the Euroanaesthesia and Focus Meeting congresses that serve as platforms for cutting-edge science and innovation in the field. These events bring together experts, foster networking, and facilitate knowledge exchange in anaesthesiology, intensive care, pain management, and perioperative medicine. Euroanaesthesia is one of the world’s largest and most influential scientific congresses for anaesthesia professionals. Held annually throughout Europe, our congress is a contemporary event geared towards education, knowledge exchange and innovation in anaesthesia, intensive care, pain and perioperative medicine, as well as a platform for immense international visibility for scientific research.


Back

Professional Growth

The ESAIC's mission is to foster and provide exceptional training and educational opportunities. The ESAIC ensures the provision of robust and standardised examination and certification systems to support the professional development of anaesthesiologists and to ensure outstanding future doctors in the field of anaesthesiology and intensive care.


Back

Research

The ESAIC aims to advance patient outcomes and contribute to the progress of anaesthesiology and intensive care evidence-based practice through research. The ESAIC Clinical Trial Network (CTN), the Academic Contract Research Organisation (A-CRO), the Research Groups and Grants all contribute to the knowledge and clinical advances in the peri-operative setting.


Learn more about the ESAIC Clinical Trial Network (CTN) and the associated studies.

pink fluid being poured into many test tubes
Back

EU Projects

The ESAIC is actively involved as a consortium member in numerous EU funded projects. Together with healthcare leaders and practitioners, the ESAIC's involvement as an EU project partner is another way that it is improving patient outcomes and ensuring the best care for every patient.


image of a stethoscope laying on the european flag
Back

Patient Safety

The ESAIC aims to promote the professional role of anaesthesiologists and intensive care physicians and enhance perioperative patient outcomes by focusing on quality of care and patient safety strategies. The Society is committed to implementing the Helsinki Declaration and leading patient safety projects.


Back

Sustainability

To ESAIC is committed to implementing the Glasgow Declaration and drive initiatives towards greater environmental sustainability across anaesthesiology and intensive care in Europe.


Back

Partnerships

The ESAIC works in collaboration with industry, national societies, and specialist societies to promote advancements in anaesthesia and intensive care. The Industry Partnership offers visibility and engagement opportunities for industry participants with ESAIC members, facilitating understanding of specific needs in anaesthesiology and in intensive care. This partnership provides resources for education and avenues for collaborative projects enhancing science, education, and patient safety. The Specialist Societies contribute to high-quality educational opportunities for European anaesthesiologists and intensivists, fostering discussion and sharing, while the National Societies, through NASC, maintain standards, promote events and courses, and facilitate connections. All partnerships collectively drive dialogue, learning, and growth in the anaesthesiology and intensive care sector.


Back

Guidelines

Guidelines play a crucial role in delivering evidence-based recommendations to healthcare professionals. Within the fields of anaesthesia and intensive care, guidelines are instrumental in standardizing clinical practices and enhancing patient outcomes. For many years, the ESAIC has served as a pivotal platform for facilitating continuous advancements, improving care standards and harmonising clinical management practices across Europe.


Back

Publications

With over 40 years of publication history, the EJA (European Journal of Anaesthesiology) has established itself as a highly respected and influential journal in its field. It covers a wide range of topics related to anaesthesiology and intensive care medicine, including perioperative medicine, pain management, critical care, resuscitation, and patient safety.


Back

Membership

Becoming a member of ESAIC implies becoming a part of a vibrant community of nearly 8,000 professionals who exchange best practices and stay updated on the latest developments in anaesthesiology, intensive care and perioperative medicine. ESAIC membership equips you with the tools and resources necessary to enhance your daily professional routine, nurture your career growth, and play an active role in advancing anaesthesiology, intensive care and perioperative medicine.


Membership opportunities
at the ESAIC

woman showing another woman something on her computer in a hospital

Newsletter 2022

Clinical corner - Beyond ‘No trace = wrong place’. The complexity of capnography and ET tube placement.

Dr Cheah Kean Seng MBBS, FCAI
dkscheah@gmail.com

Wallace Wattles, an American author once said, ‘It is essential to have good tools, but it is also essential that the tools should be used in the right way’. This quote couldn’t be more legitimate in describing our use of capnography in practice. The use of capnography is still far from universal and thorough understanding despite its first introduction in the United States in 1978. In one survey of 315 ICU units across the UK and the Republic of Ireland, less than half (32% to be exact) actually commit to the use of capnography for intubation and monitoring of patients on a ventilator(1).

bigstock ventilator monitor and african 418187860

According to NAP4 Major Complications of Airway Management, the diagnosis of oesophageal intubation was hampered by the lack of capnography use. In NAP4 there was a total of 9 cases of unrecognised oesophageal intubation were reported. All outcomes were poor, leading to 6 deaths and 1 irreversible brain damage(2). It is also proven that clinicians, mostly anaesthetists, repeatedly fail to recognise that flat capnography indicates the absence of ventilation and a displaced ET tube. Zero trace capnography often being misinterpreted as the consequence of cardiac arrest, which is incorrect. When the ET tube is in the correct position with the presence of ventilation, the high CO2 in the pulmonary circulation will continue to diffuse, producing a low trace (4mmHg), unlike the totally zero traces seen in oesophageal intubation.

In the past, it was believed that capnography would not be able to accurately confirm the ET tube placement due to low CO2 diffusion in a low cardiac output state, like during cardiac arrest. This statement can be true with the use of colourimetric CO2devices due to the low sensitivity of the colour change in low CO2 concentration. However, replacing colourimetric with waveform capnography changes the situation completely. Waveform capnography has high sensitivity and specificity in the detection of oesophagal intubation(3). The 2010 International Consensus guidelines on cardiopulmonary resuscitation specifically mentioned the use of capnography to confirm advanced airway placement during CPR.

Since then, the Royal College of Anaesthestists and Difficult Airway Society launched the campaign ‘No trace = Wrong place’  to remind the anaesthetist to recheck tube placement to prevent oesophageal intubation from going undetected for a long period of time and the delay in correction leading to death.

A recent article ‘No trace, the wrong place does not mean positive trace, correct place’(4) written by Dr Pandit is particularly interesting. The author highlights the logical fallacy of reversing the slogan of ‘No trace = wrong place’. Truth be told, ‘No trace = wrong place‘ is a contra-negative statement. Assuming that ‘if not A = not B’ does not validate ‘if A = B’ true. This can relate to ‘Positive trace does not always mean right place’ as there are outliers in an area of ambiguity.

What is the outlier that the tube can be in ‘right place but no trace’, or ‘wrong place but with trace’?

Figure 1

Figure 1: Two scenarios result shifting away from the commonly seen ‘No trace + wrong place’ situation (white column). The rightward shift leads to the causes of ‘No trace’ (blue outlier). The leftward shift leading to ‘Wrong place’ category (red outlier).

Dr Pundit further explained that correct placement can be defined anatomically (tracheal vs non-tracheal) or physiologically (alveolar ventilation vs non-ventilation). An anatomically ‘correct’ placement could be physiologically ‘wrong ‘if without alveolar ventilation (such as tracheo-oesophageal fistula or inadequate tidal volume generation). This condition together with faulty capnography, tube blockage or leakage will fall under the blue outlier umbrella in Figure 1.

Oesophageal intubation can also fall under a scenario of ‘positive trace + wrong place’ (red outlier) by false-positive capnography if the patient has recently ingested a carbonated drink prior to intubation. No one can quantify the amount of carbonated drink that needs to be ingested to produce a false positive result but it was reported in a trial of the high sensitivity of capnometer to detect ETCO2 after carbonated drink was 100% (cuff tube) and 67% (cuff + uncuff tube)(1).

A displaced ET tube either too deep into the endobronchial or too shallow in the upper airway could produce a trace despite being in the wrong position. Endobronchial intubation will result in a biphasic capnography wave whereas an ET tube that is situated in the upper airway in a spontaneously breathing patient could produce a minimal trace of ETCO2 as well. Migration of the tube is common especially during chest compression despite a well-secured ET tube although a tube holder fixation method reported less shift than other types of fixation (durapore/multipore) in one study(2). Despite a tightly secured ET tube, the position of the tube in the trachea could change still due to the physiological ‘to and fro’ movement of the trachea. Herway and Benumof described this as ‘tracheal accordion’(3). Tracheal accordion occurs due to dynamic changes (anaesthesia, tredelenburg position, during CPR) causing the trachea to act as the musical instrument accordion, increasing and decreasing its length that eventually alters the position of the tube. This might play a role although its significance of it remains unclear.

The suspension of NHS to include unintended oesophagal intubation in ‘Near event’ occurred due to the concern raised by the British Association of Perinatal Medicine (BAPM). Waveform capnography is not a standard of care in intubated neonates partly due to uncuff ET tubes. In contrast to the cuff ET tube, the expiration of CO2 usually occurs along the side of uncuff tube and not through it, making the detection of ETCO2 difficult. Administration of surfactant in preterm neonates could obstruct the outflow of CO2. Therefore initial flat capnography is commonly seen in neonates and can be misinterpreted as displacement. Both the RCUK Newborn Life Support (NLS)(4) and Advanced Resuscitation of the Newborn Infant (ARNI)(5) courses currently recommend ETCO2 detection rather than waveform capnography. An updated version is due to be published soon.

In summary, the association between capnography and ET tube placement may sound complex, yet it does not contradict the simple slogan of ‘No trace = wrong place’ because awareness of this often leads to timely correction of mistakes that can save lives and change patient’s outcome entirely.

References

  1. Georgiou AP, Gouldson S, Amphlett AM. Anaesthesia. 2010 May;65(5):462-7.
  2. Cook, TM, Woodall, N, Frerk et al. Royal College of Anaes. London; 2011.
  3. Silvestri S, Ladde JG, Brown JF et. Resuscitation. 2017 Jun;115:192-198.
  4. Pandit JJ. Anaesthesia. 2022 Jan;77(1):16-21.
  5. Keller WR, Biehler J, Linares MY et al. Paediatr Emerg Care. 2009 Feb;25(2):69-73.
  6. Komasawa N, Fujiwara S, Miyazaki S et al. J Emerg Med. 2015 Feb;48(2):241-6.
  7. Herway ST, Benumof JL. Anaesth Intensive Care. 2017 Mar;45(2):177-188.
  8. Resuscitation Council (UK). Newborn life support (4th edn.)
  9. Resuscitation Council (UK). Advanced resuscitation of the newborn infant.